4.3.3

Version with through hollow shaft

Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder.
)
» Lubricate drive shaft!
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
>113 mm
The encoder must be mounted with cable connection facing downward and not
i
exposed to water.
MB246EN - 11171695, 16A3, Baumer_HMG10-ProibusDP_II_EN
12�
ød (mm)
16
h6
20
h6
10b
10c
MOUNTING / MOUNTING TO DRIVE SHAFT
Loosen the screw
8b
5
10a
10c
10e
10b
10d
1�6x8 mm
Tighten the screw
Mt = 2-3 Nm
section 4.5,
TX 10
8c
9
10b
10c
10 mm