Baumer HUBNER POG 10 G Series Instructions de montage et d'utilisation - Page 29

Parcourez en ligne ou téléchargez le pdf Instructions de montage et d'utilisation pour {nom_de_la_catégorie} Baumer HUBNER POG 10 G Series. Baumer HUBNER POG 10 G Series 32 pages. Incremental encoder (twin encoder)
Également pour Baumer HUBNER POG 10 G Series : Manuel d'installation et d'utilisation (36 pages), Instructions de montage et d'utilisation (36 pages), Instructions de montage et d'utilisation (28 pages), Instructions de montage et d'utilisation (32 pages)

Baumer HUBNER POG 10 G Series Instructions de montage et d'utilisation
9

Technical data

9.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
3)
MB160 - 11055773
Baumer_POG10-POG10G-HARTING_II_DE-EN (19A2)
9...30 VDC
(HTL-P, TTL - version R)
3)
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted
HTL-P (power linedriver); TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø115 mm
ø11 mm solid shaft
≤300 N axial, ≤450 N radial
EURO flange B10
IP66
≤12000 rpm (mechanical)
2 Ncm
212 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 200 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Harting connector HAN® 10 A + HAN® 15 D
1.9 kg
2.5 kg (option G)
Technical data
9
26