MOUNTING / MOUNTING THE SPRING DISK COULING TO THE ENCODER
4.
MOUNTING
4.1
Mounting the spring disk couling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
9, available as accessory� When other couplings are used pay attention to manufactu-
rer's notes�
)
4.2
Mounting to drive shaft
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error�
High runout of the drive shaft can cause vibrations, which can shorten the lifetime of
the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
7/21
2�5 mm
8
M
= 100 Ncm
t
7
10 mm
6
MB249EN - 11171701, 16A3, Baumer_PMG10-PROFINET_II_EN