Baumer CombiLyz AFI5 Manuel

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Baumer CombiLyz AFI5. Baumer CombiLyz AFI5 7 pages. Conductivity transmitter
Également pour Baumer CombiLyz AFI5 : Instructions d'utilisation (36 pages)

Baumer CombiLyz AFI5 Manuel
TYPE EL - CLASS I
DECEMBER 2012
Technical specifications
Housing material
Cable (AFI5)
Material
Temperature
Process connection
Insertion length
Standard
Medium
Long
Material
Not wetted
Wetted parts
Surface
Wetted parts
Measuring range
Conductivity
Concentration
Temperature
Accuracy
Cond./conc.
(sensor incl. transmitter
@ 25°C ambient)
Temperature
Temperature compensation
Compensation range
Reference temperature
Sampling time
Response time
Cond./conc.
Temperature
Start up time without display
Start up time with display
www.baumer.com
FlexHousing, Ø80 mm
Stainless steel, AISI 304
2.5 / 5.0 / 10.0 meter
PUR
-40...80°C
G1B hygienic, rotating
(for other connections see adap-
ters page 4)
37 mm / hygienic version 41 mm
60 mm / hygienic version 64 mm
83 mm / hygienic version 87 mm
Stainless steel AISI 304
PEEK natura, unfilled
Ra < 0.8 µm
0 ... 500 µS/cm ... 0 ... 1000 mS/cm
14 selectable ranges
4 factory set media/ranges
1 customer defined media/range
-30 ... 150°C
Free programmable range
0 ... 500 µS/cm
≤ 1.5 %
0 ... 1 / 0 ... 500 mS/cm ≤ 1.0 %
0 ... 1000 mS/cm
≤ 1.5 %
≤ 0.4°C
0.0 ... 5.0% / K, free adjustable
-20 ... 150°C
25°C (adjustable)
< 0.3 second
t
< 2.0 seconds
90
t
< 15 seconds
90
≤ 10 seconds
≤ 15 seconds
CombiLyz AFI4 / AFI5
Inductive conductivity transmitter
Main features
Range from 500 µS/cm to
„
„
1000 mS/cm
All hygienic design
„„
Built in graphical display
„„
CombiView DFON
Very fast temperature compen-
„
„
sation
Easy and full programmable
„
„
with FlexProgrammer 9701
AFI5 split version with remote
„
„
Applications
Controlling CIP procedure
„
„
Controlling filling machines
„
„
Detection of specific medias
„
„
Water systems with >50 µS/cm
„
„
Electrical specifications
Power supply
Output
Cond./conc.
Temperature
Relays
Display
(for more information
please see page 3)
Temperature drift Conductivity
Temperature
El. connection
Left side
Right side
Material
General specifications
Media temperature
Media pressure
Ambient
Without display
temperature
With display
Isolation voltage
Protection
EN60529/A2:2013 IP67 / IP69K
class
Humidity
IEC 68.2.38
Vibrations
1)
Factor of change in process temperature from 25°C
2)
Range 0...500 µS/cm ≤0.3%/K
Data sheet AFI4 / AFI5
sensor
Separate 4...20 mA output
„
„
for conductivity / concentra-
tion and 4...20 mA output for
temperature
FDT software
„
„
3-A approved
„
„
EHEDG
„
„
Touch screen
„
„
15 ... 35 VDC
4 ... 20 mA
4 ... 20 mA + HART
®
4 ... 20 mA
2 relays included in the display
Without display
With DFON display, 2 relay-output
galvanic separated
≤ 0.1%/K
1) 2)
≤ 0.5%/K
1)
AFI5: ≤ 0.5%/K + 0.005%/K pr. m
sensor cable
M12, 4-pin
M16 or M20 cable gland
M12, 4-pin (4 ... 20 mA output only)
M12, 8-pin (4 ... 20 mA + relay output)
M16 or M20 cable gland
Plastic (PA)
Stainless steel
-20 ... 140°C
150°C up to 1 hour
< 25 bar (helium tested)
-40 ... 85°C
-30 ... 80°C
500 VAC
98% condensing
IEC 60068.2.6 - test Fc
1.0 mm (2-13.2 hz) 0.7g (13.2-100 hz)