7.2.5
Measuring the encoder supply (menu
After connecting up a incremental encoder, it is recommended to check the supply to
the encoder�
For this purpose, the HENQ 1100 offers the option in menu
supply voltages present at the encoder connection (5 V and 9���30 V), the current
drawn (in mA) and the power consumption (in mW)�
This makes it easy to detect wiring errors, such as a short-circuit or cable break, or
an encoder fault�
The current drawn by the output driver that is integrated in the HENQ 1100 is shown
in the last line of the display� This will only be non-zero if the encoder signals provi-
ded by the HENQ 1100 are passed on to a control system, see
10�
Fig.15:
Fig.16:
MB112EN - 11185046, 19A1, Baumer_HENQ1100_OI_EN
Display menu
Version without accumulator
Display menu
Version with accumulator
OPERATION / MENU DESCRIPTION
)
U1
HTL supply voltage
(9���30 V)
U2
5 V supply voltage
UB
Accumulator supply voltage
(only in devices equipped with
accumulator)
ID
Current consumption of the output
driver
of displaying the
section 6.2.2, page
22/32