Baumer OM30 Manuel d'utilisation - Page 21

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Baumer OM30. Baumer OM30 48 pages. Laser distance sensors

Baumer OM30 Manuel d'utilisation
Baumer
7

Commissioning

7.1

Factory settings

Adjustable parameters
Operation Mode
Measurement Range
Invalid Value Handling
SSC1 Configuration
Input/Output Settings
Analog Output
Local User Interface
Device Access Locks
I
Type OM20-P0026.xx.xxx: SSC1 Param.SP 1 = -2 mm
II
Type OM20-P0026.xx.xxx: SSC1 Param.SP 2 = +2 mm
7.2

Setting up IO-Link

Instruction:
w Download the IODD file for the sensor from one of the following two websites (the IODD file
can be found via the item number of the sensor):
www.baumer.com
or
ioddfinder.io-link.com
OM20/OM30 | V1
Precision Filter
Sampling Mode
Zero Position
Distance Near
Distance Far
Value after Dropout
Hold Time
SP 1
SP 2
Polarity
Mode
Hysteresis
OUT1 Mode
(Output & LED function)
Output Type
Output Characteristic
Distance @AnalogMin
Distance @AnalogMax
Local Teach Mode
Button Time Out
Data Storage Lock
Operating Manual
Commissioning
Factory setting of the sensor
Highest
Free Running
0 mm
Sdc
Sde
Near
0 ms
I
Sde -10 mm
II
Sdc +10 mm
Active High
Window
depending on MR
SSC1 - Alarm
4 ... 20 mA /
0 ... 10 VDC
Not inverted
Sdc
Sde
XPert
5 min
False
|
7
21