AW315 - Operator Manual

Electrical Safety

WARNING! Switch off and remove the plug from the mains before adjusting,
cleaning or if the cable is cut, damaged or entangled.
This welding unit is Class 1 and requires an earthed connection. (An earth spike must
be used with generators.) The operating voltage is 110 volts ac 50 Hz, and a power
source capable of 3500 Watts is required.
Extension cables should only be used if they comply with the H07RNF harmonized
standard. They must be fitted with connectors to the BS EN 60309-2 standard. All
cables must be unwound from the reel to stop inductive heating effects. The cable
dimensions should be as follows:
• 1.5mm2 cable = 25m
• 2.5mm2 cable = 50m
• 4.0mm2 cable = 75m
It is recommended for increased electrical safety to use a Residual Current Device
(RCD) with a tripping current of not more than 30 mA. Always check your RCD every
time you use it.
The supply cable must be inspected for signs of damage before each use and the
equipment may only be used if in perfect condition. Damaged cables must be
replaced by an approved service agent.
This equipment is classified as "Portable for use on industrial applications", and must
undergo a formal electrical safety check (Portable Appliance Test) every six months.