Baumer ITD 4 +KTD 3-1 B10Y8 Series Manuel d'installation et d'utilisation - Page 15
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Baumer ITD 4 +KTD 3-1 B10Y8 Series. Baumer ITD 4 +KTD 3-1 B10Y8 Series 21 pages. Tachogenerators and combinations (1-piece)
- 1. Allgemeine Hinweise
- 2. Bestimmungsgemässer Gebrauch
- 3. Besondere Sicherheitshinweise
- 4. Elektrischer Anschluss
- 5. Technische Daten
- 6. General Remarks
- 7. Appropriate Use
- 8. Special Safety Precautions
- 9. Mechanical Mounting
- 10. Installation
- 11. Electrical Connection
- 12. Maintenance, Repair & Disposal
- 13. Dimensional Drawings
- 14. Technical Specifications
6.
Electrical connection
6.1. Safety instructions for electrical connection
• Warning! Observe the additional safety precautions in chapter 4.
• Warning! Danger of electric shock!
Make sure tachogenerator is not live for the time of electrical commissio-
ning!
Switch off power supply of any equipment involved!
Ensure proper grounding!!
6.2. Electrical commissioning
• Connect protective earthing conductor to terminal M4-PE (ground).
• Remove terminal box cover (with the "Thalheim" label).
• Use a mating cable to connect terminal box at Pg7.
• Assign the terminals.
• A1 = + ; A2 = - at cw rotation
• Only use cables
recommended by Baumer.
• Close terminal box cover.
Shaft design as product combination:
KTD 3-... + ITD 2... B10; ITD 4.... + KTD 3-... B10...
• Connect cable respectively flange connector of the incremental encoder. For
terminal assignment please see data sheet.
7. Maintenance, repair & disposal
• Any repair work or opening of the tachogenerator by the manufacturer only.
• Dispose of all integrated components in compliance with the country-specific
provisions.
Baumer_KTD3A4-KTD3B10-KTD3-Kombinationen_OI_DE-EN_1606.indd
max. 1.2 Nm
Drehrichtung Welle
-
+
A 1
A 2
Tacho-
generator
A1 A2
Motor
15