Asus AR1000 Manuel de référence du matériel - Page 31
Parcourez en ligne ou téléchargez le pdf Manuel de référence du matériel pour {nom_de_la_catégorie} Asus AR1000. Asus AR1000 32 pages. Raid subsystem
IV. Hardware Setup
Power Module Rating
The power modules are rated at 350W each and have passive current shar-
ing on all outputs. Each power module supplies up to 350W to share the
load, but two modules combined do not provide 700W. If one power mod-
ule fails, 350W load is supported by using the other power module.
NOTE
This product has autoranging input to accommodate 220V-240V
or 110-120V. You do not have to set it manually.
Power Module Failure
If any of the power modules fails to provide a voltage on any of its outputs,
an audible alarm (located in the frame) will sound and the failed power
module's LED will turn OFF. The power module's status LED lights when
both input and output voltages are stable and darkens if either the input or
output voltages fail. If the alarm sounds, perform the following steps:
1. Remove the power cord to the failed power module (with unlit LED).
2. Remove the two screws and slide the failed power module out. The
alarm should stop. If not, there may be a problem with the other module
or with the redundant power supply frame (very unlikely).
3. Reinsert the failed power module and plug in the AC cord to confirm.
4. If the alarm sounds again, remove the failed power module and replace
it with a good one as soon as possible.
AR1000 RAID Subsystem Hardware Reference Guide
31