4.5.3 Defectpixellist

As stated previously, this list is determined within the production process of Baumer cam-
eras and stored in the factory settings (see 4.8.1.).
Additional hot or cold pixels can develop during the lifecycle of a camera. In this case 
Baumer offers the possibility of adding their coordinates to the defectpixellist. The user 
can determine the coordinates
defect pixel list is stored in a user set (see 4.8.), pixel correction is executed for all coor-
dinates on the defectpixellist.

4.6 Process Interface

4.6.1 IO Circuits
Output high active
Camera
Customer Device
IO Power V CC
I OUT
R L
IO GND
*) 
Position in relation to Full Frame Format.
 of the affected pixels and add them to the list. Once the 
*)
Output low active
Camera
Customer Device
IO Power V CC
R L
I OUT
IO GND
Input
Customer Device
Camera
DRV
IO GND
23