Baumer EXG50c Manuel de l'utilisateur - Page 33
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Baumer EXG50c. Baumer EXG50c 42 pages. Gigabit ethernet
5.6 Message Channel
The asynchronous message channel is described in the GigE Vision
the possibility of event signaling. There is a timestamp (64 bits) for each announced event,
which contains the accurate time the event occurred. Each event can be activated and
deactivated separately.
5.6.1 Event Generation
Event
Gen<i>Cam™
ExposureStart
ExposureEnd
FrameStart
FrameEnd
Line0Rising
Line0Falling
Line1Rising
Line1Falling
Line2Rising
Line2Falling
Line3Rising
Line3Falling
Line4Rising
Line4Falling
Line5Rising
Line5Falling
Vendor-specific
EventError
EventLost
TemperatureExceeded
TriggerReady
TriggerOverlapped
TriggerSkipped
Notice
By the individual cameras of the Baumer EXG series the GigE Vision
nel is supported in different degrees.
Description
Exposure started
Exposure ended
Acquisition of a frame started
Acquisition of a frame ended
Rising edge detected on IO-Line 0
Falling edge detected on IO-Line 0
Rising edge detected on IO-Line 1
Falling edge detected on IO-Line 1
Rising edge detected on IO-Line 2
Falling edge detected on IO-Line 2
Rising edge detected on IO-Line 3
Falling edge detected on IO-Line 3
Rising edge detected on IO-Line 4
Falling edge detected on IO-Line 4
Rising edge detected on IO-Line 5
Falling edge detected on IO-Line 5
Error in event handling
Occured event not analyzed
Reference value of temperature exceeded
t
(see chapter 2.4) elapsed, camera is able to
notready
process incoming trigger
Overlapped Mode (see chapter 2.4) detected
Camera overtriggered (see chapter 2.4)
standard and offers
®
Message Chan-
®
33