Figure 10 ►
Single Tap Readout
Mode.
12
6.1.3.3.
Single Mode
In single readout mode all taps are combined as displayed in the subsequent figure.
The data of all pixels of the sensor are moved to the output register and afterwards trans-
fered to the memory.
Once the information have left the output register, the readout is done. 
Due to the fact, that the complete sensor needs to be read out, the readout time t
increased compared to quad and dual readout mode.
It is considered:  
t
 ≈ 4 × t
readout(Single Mode)
readout(Quad Mode)
is
readout