Baumer NE216 Manuel d'utilisation - Page 14

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Baumer NE216. Baumer NE216 22 pages. Electronic preset counter

NE216
Line 21
Line 22
Line 23
Line 24
Line 30
Line 31
Line 32
Line 33
36
Programming field 3
All functions and values as well as interface parameters conditioned
by the machinery are programmed here.
Each factory setting is marked as such by *.
Operating modes main counter
0 * Adding, final signal at P2, reset to SC
1
Subtracting, final signal at SC; if programming with automatic
reset (Line 23), it is effected at SC
2
Subtracting, final signal at SC; if programming with automatic
reset (Line 23), it is effected at 0.
Preset mode
0 * Step preset
1
P1 - Trailing preset
Reset modes
0 * With automatic reset
1
Without automatic reset
Decimal point for PC, P1, P2, SC, tot
0 * No decimal point
1
0000.0
2
000.00
3
00.000
Counting mode
0 * Counting input track A, reversal track B
1
Subtraction track A adding and track B subtracting (A-B)
2
Totaling track A adding and track B adding (A+B)
3
Track A 90° B single evaluation
4
Track A 90° B double evaluation
5
Track A 90° B quadruple evaluation
In case of the counting mode „Track A 90° B" , the frequency of
Track A and B, Line 31 and 32, has to be adjusted to 10 kHz.
6
Time meter with preset. Counting while track A active. Track B
has no function.
7
Time meter with preset. Counting started via track A and stop-
ped via track B. Track A and B edge-triggered.
The time range is selected in line 43.
Frequency main counter track A
0 * 10 kHz
1
25 Hz
1
3 Hz
Frequency main counter track B
0 * 10 kHz
1
25 Hz
2
3 Hz
Input logic and operating threshold of signal inputs
0 * PNP Operating threshold 6 V
1
NPN Operating threshold 6 V, or for Namur without Ex. protection
2
PNP Operating threshold 3 V
3
NPN Operating threshold 3 V
www.baumer.com