Amphenol Procom CSR-DMT Manuel de l'utilisateur - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Amphenol Procom CSR-DMT. Amphenol Procom CSR-DMT 16 pages. Bi-directional digitally controlled amplifier that offers an increase of signal strength in small and medium-sized rooms.

3.2 Electrical installation

Electrical installation must be performed in accordance with all the local regulations. Electrical
installation must be performed by qualified personnel only. Do not open repeater case without
required qualification!
For details about connectors see "2.5 Connectors, indicators, buttons" section of this manual.
1.
Connect donor and indoor antennas to corresponding RF ports.
2.
Align donor antenna toward desired BTS.
3.
If 230VAC cord will be connected right at site, see right electrical clamp types.
4.
Check all connections/nodes one more time.
5.
Connect 230 V AC cable.
1.
In case it is needed, connect USB to CSR-DMT and run PROCOM A/S control software
to reconfigure repeater.
6.
See activity of AGC LEDs. For details refer to section "2.4 Hardware AGC".

3.4 Driver installation

Microsoft Windows 7 and later already ship with required driver to run Procom control software.
In case of Windows XP run 'CDM v2.12.10 WHQL Certified.exe' file.

4.0 CONTROL SOFTWARE

4.1 System requirements

CSR-DMT control software requires a personal computer with:
At least one USB port and
Microsoft Windows XP, Vista, 7 or 8 operating system
(both 32 bit or 64 bit systems are supported).

4.2 Overview

CSR-DMT control software is a GUI tool for repeater configuration. It can be used to set repeater
frequency response, adjust gain and monitor health state.
Configuration interface (see section "4.4 Configuration interface" of this manual) is used to:
set repeater frequency response,
adjust gain and control software AGC settings,
store predefined configurations,
monitor measurements and health state,
remotely turn repeater on and off.
CSR-DMT repeater can store up to 16 different filter configurations. Each configuration stores not only the
filter settings, but also power and software AGC settings. However, there can be only one active
configuration.

4.3 Establishing a connection

On DR_Ctrl startup "Select Communication Channel" dialog appears. Select the COM port that is
connected to the repeater and press 'OK'. Program will proceed to load repeater configuration.
Page 12 of 16