Dover Hydro systems 595 Manuel de démarrage rapide

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Dover Hydro systems 595. Dover Hydro systems 595 2 pages. Single solid dissolver

Dover Hydro systems 595 Manuel de démarrage rapide
Troubleshooting Chart:
Problem
Cause
1. System does not operate
a. No water
b. Clogged water inlet strainer
c. Water valve failure
2. Discharge from siphon
a. Failed siphon breaker
breaker
3. Float is not turning water
a. Unit not level
flow On/Off
b. Float movement obstructed
4. Solution strength too low
a. Low inlet pressure
b. Inlet tubing kinked
Note: Colder water temperatures result in a decrease in the chemical dissolve rate.
* Hard water may cause build-up of mineral deposits in water valve. Remove deposits by soaking the valve parts
in a deliming solution.
3798 Round Bottom Road, Cincinnati, OH 45244 U.S.A. • Phone: (513) 271-8800 • Fax: (513) 271-0160 •www.hydrosystemsco.co
Solution
a. Open water supply
b. Disconnect inlet water line and clean
strainer
c. Clean or replace with valve parts kit*
a. Repair or replace siphon breaker
a. Make sure unit is level - float hangs level
b. Make sure float movement is not
obstructed
a. Adjust inlet pressure higher using
reguator 30-40psi is recommended
(Turn pressure adjustment screw
clockwise to increase pressure)
Make sure tubing is not kinked
b. Adjust tubing to prevent kinking
10091940
Rev. F 4/15
Single Solid Dissolver
THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS
Please use this equipment carefully and observe all warnings andcautions.
*************************************************** NOTE ********************************************
protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals,
WEAR
filling or emptying equipment, or changing metering tips.
observe safety and handling instructions of the chemical manufacturer.
direct discharge away from you or other persons or into approved containers.
ALWAYS
install solid dissolver in an area with a floor drain nearby, and connect overflow port with hose to drain.
dispense cleaners and chemicals in accordance with manufacturer's instructions. Exercise CAUTION when maintaining your
equipment.
reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.
KEEP
equipment clean to maintain proper operation.
UNIT SPECIFICATIONS:
Weight: -- 15lb. Dry
-- 35lb. With full chemical bottle and full solution reservoir
Dimensions: -- 14" W X 24" H X 10" D
1. Drill holes for the four wall
2. Install the siphon breaker
anchors with a (9/32") drill,
by pushing the 1/4" fitting on
using the mounting board as
the metal tube and the 3/8" fit-
a template. Make sure the
ting on the flexible black tube.
board is level.
4. Install the float on the S-
5. Connect water supply line
hook inside the board.
to the inlet ball valve push-in
Verify float operation is not
fitting.
obstructed.
Package Should Contain:
1. Dissolution Board
595
2. Float
3. S-hook
4. Siphon Breaker
5. Outlet Ball Valve
6. Mounting Kit
7. Overflow Fitting
8. Instruction Manual
3. Remove top screw from
black access panel to install
float.
6. Install the outlet ball valve
using thread sealant.
Continued