AmpleNess S52200 Manuel de l'utilisateur - Page 14

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} AmpleNess S52200. AmpleNess S52200 18 pages. Home energy storage system (split type)

6.4.5 Communication wire connection
A single battery: just select the corresponding interface according to the communication
protocol of inverter.
Multiple batteries: the host and the slave batteries communicate in cascade mode, thereinto,
one of them is the host, and the rest are slave batteries. Please take reference for cascade
wiring of the above map. Then, the corresponding port can be connected to the host battery
according to the communication protocol of inverter.
6.4.6 Start-up
1) Please confirm again whether all cables are correctly connected, firmly connected, and not
short circuit or reverse connection before starting up.
2) Please turn all battery switch buttons to "ON" .
3) A single battery: If the battery SOC indicator is always on and the alarm indicator is off, it
means that the battery has been started.
4) Multiple batteries: If all battery SOC indicators are always on and the alarm indicator is off,
it means that all batteries have been started.
Attention: please connect the inverter immediately to charge if battery power is too low
and cannot be started.
6.4.7 Power-on test
1. Please connect battery and inverter or DC switching power supply.
2. Please check whether battery state is normal according to the indicator table:
a. battery will be in charging mode if battery power is not full and inverter has successfully
charged to battery.
b. battery will be in standby mode if battery power is full and is not supply power to loads.
c. battery will be in discharging mode if battery is supply power to loads.
User Manual of Home Energy Storage System (Split Type)
Wiring harness in
parallel
Communication harness
in parallel
Wiring harness
the inverter wiring harness
14