Follett HCC1010A Manuel de l'utilisateur - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Follett HCC1010A. Follett HCC1010A 16 pages. Ice machines (self-contained) 50 hz and 60 hz

Follett HCC1010A Manuel de l'utilisateur

Specifications

Electrical
Each ice machine requires its own separate circuit with electrical disconnect within 10 ft (6 m).
Equipment ground required.
Standard electrical:
§ HCE1010: 230/50/1 (6 ft (2 m) cord) requires dedicated 15A circuit
§ HCE1410: 230/50/1 (6 ft (2 m) cord only, no plug) requires dedicated 20A circuit
§ HCC1010: 208-230/60/1 (6 ft (2 m) NEMA 6-15 cord and plug provided) requires dedicated 15A circuit
§ HCC1410: 208-230/60/1 (6 ft (2 m) NEMA 6-20 cord and plug provided) requires dedicated 20A circuit
§ Amperage: 1010A/W - 11A,
1410A/W - 14A
Plumbing
This equipment to be installed with adequate backflow protection to comply with applicable federal, state, and
local codes.
§ 3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required
§ 3/4" MPT drain
§ 1/4" FPT condenser inlet (water-cooled condenser only)
§ 1/4" FPT condenser drain (water-cooled condenser only)
Notes:
§ Water shut-off recommended within 10 feet (3 m).
§ Water supply must have particle filtration. Follett recommends the filter system that has integral scale inhibitors.
(Follett item# 00130286).
§ Follett does not recommend the use of water softeners or bowl scale inhibitors.
§ The potable water total dissolved solids (TDS) content must be greater than 10 ppm for the water control
system to function properly. If using reverse osmosis water filtration system, ensure TDS level is greater than
10 ppm.
Flush drain plumbing
§ 3/4" MPT flush drain connection at the rear of the machine.
§ Drain must slope 1/4" per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1".
§ Drain should be piped without a vent.
Horizon Elite 1010/1410 Self-Contained (50 Hz and 60 Hz)
3/4" barb x 3/4" FPT
2 ft. x 1" OD
silicone tubing
1/4" per foot
(6,4 mm per 0,3 m)
1'
WARNING
3/4" MPT x 1" slip
1" PVC Drain
3/4" barb x 3/4" FPT
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
1" Stand pipe/Drain
3