Combi-Cam miniK 10 Manuel d'utilisation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Combi-Cam miniK 10. Combi-Cam miniK 10 9 pages. E series electronic cabinet lock

PROGRAMMING OPTION DEFINITIONS:
Restoring factory settings: All factory default settings are restored (see
0
program menu). User password becomes <1-0-1-0> and master password
becomes <1-0-1-0-1-0>.
1
Individual Use or Locker Mode: Factory default is locker mode (one time
use) whereby each user that walks up to an open MiniK10 can enter their 4-
digit code to close and open lock. Every person can enter their own new code
when lock is in open mode. Individual use mode allows one 4-digit static code
to be entered that would remain same code for one user.
Audible volume control: All audio warnings can be turned off if mute
2
operation is selected (except warning beeps).
Penalty operation: Prevents tampering of lock by unauthorized people. Lock
3
is blocked for 5 minutes if wrong password is entered three times
consecutively. Factory default is that this feature is not active.
This programming function is currently open for placing a future feature
4
Service password: Lock can be opened with service password if user
5
password is forgotten. Factory service default password is <1-0-1-0-1>. No
programming features can be accessed with service password. Factory
default is that this feature is not active.
Closing modes: Factory default is that the MiniK10 requires a password to
6
lock. The other option is it can be locked without requiring a password.
7
Door open warning: After door is open for one minute, lock gives an audible
warning to user with 8 beeps every 5 seconds to notify user that the door has
been left open.
8
Resetting user password: If the lock is opened with service password (and
service password is active), user password can be reset. (see program #5 on
service passwords). Factory default is that the service password access does
not allow the user password to be reset (only opens up the lock).
9
Blocking the lock: If lock opened with service password, it can be blocked
from further user password access
used to access locks for emergency lockouts. Master password access would
then be required to set up user password again (0-1 Factory default reset).
Factory default is that this feature is not active.
LIGHT AND AUDIO NOTIFICATION:
Password is accepted:
Wrong password:
Low battery:
Lock is open:

CHANGING THE BATTERY:

Lock operates on a 3V lithium coin cell CR2450 battery located on back side of device. Remove screw
located on cover of battery and replace it with new battery. Battery life is up to 10 years. Th red LED
light blinks 5 times after each operation when battery is low and it is possible to open and close
lock for 100-150 times after you get the initial low battery warning.
This would insure service password is only
Green LED lights with two repeated audio warnings
Red LED lights with four repeated audio warnings
Red LED lights blink 5 times after each operation
1 minute after door is opened, lock gives audible warning 8 times
every 5 seconds
.