Remote condensing unit
Condensing unit installation specifications
Important specifier notes:
1. Provide front, back and side clearances
as shown.
2. The maximum refrigerant line run length is
100' (30.5 m). Installations with up to 50'
(15.2 m) line run require:
700 Series – 8 lb (4 kg) of refrigerant
Consult installation manual for correct
refrigerant charge if line run exceeds
50 ft (15.2 m).
3. The maximum line rise above the evaporator
is 35 ft (10.7 m). Condensing unit above
evaporator unit – 35 ft (10.7 m) (installations
with rise over 20 ft (6.1 m) require additional
suction line s-trap at midpoint rise).
4. The evaporator can only be mounted
a maximum of 15' (4.6 m) above the
condensing unit.
Note: The service loop is not included
when calculating length, rise or drop in
the tubing run.
Note: To connect evaporator/ice machine to rack systems, see page 3.
Remote 700 series ice machine
24.00"
(61.0 cm)
48.00"
(121.9 cm)
air in
48.00"
(121.9 cm)
24.00"
(61.0 cm)
7
Form# 6190