Follett Horizon Elite 2110 Series Manuel d'instructions d'installation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Follett Horizon Elite 2110 Series. Follett Horizon Elite 2110 Series 13 pages. Ice machine models with ride technology
Également pour Follett Horizon Elite 2110 Series : Manuel de démarrage rapide (8 pages), Manuel d'instructions d'installation (17 pages), Manuel (8 pages)

Follett Horizon Elite 2110 Series Manuel d'instructions d'installation

Prepare the installation site.

Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
2.1
2.1
Installation site requirements
Electrical
• 120/60/1-5 amps
Potable water supply
• 10-70 psi (69-483kpa)
• 45-90 F (7-32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
• This equipment is to be installed with adequate backflow protection to comply with applicable federal,
state, and local codes
Drains:
3/4" Barb for silicone drain, 3/8" push-to-connect for chassis drain
• Minimum 8" radius on silicone drain line. Drain line from the ice machine must have at least 1/4" per foot
pitch (6,4mm/0,3m).
Refrigeration lines
• 7/8" ∅ (22,4 mm) diameter suction line (insulated)
• 3/8" ∅ (9,5 mm) liquid line
BIN • TOP-MOUNT
3/8"
drain must be
used
(3/8" push-in connection, 3/8" OD tubing required)
remote condensing
chassis
3/8" ∅ (9,5mm)
7/8" ∅ (22,4 mm)
1'
1/4" per foot
(6,4 mm per 0,3 m)

Site preparation

Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
NEMA
5-15
2
5