Follett Horizon Elite HCD1410NJS Manuel d'instructions d'installation
Connect utilities to louvered docking assembly.
6.1
Water and drain
• Remove access panel if necessary.
• Install drain line
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Rough-in ice machine potable water
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Apply Petrogel to barbed drain fitting
• Replace access panel.
10
.
remote condensing

External connections

6.2
Refrigerant
• Braze supplied expandable refrigerant
lines in place
DROP-IN  •  RIDE Technology
6