Follett Horizon Elite HCD1410NJS Manuel d'instructions d'installation - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Follett Horizon Elite HCD1410NJS. Follett Horizon Elite HCD1410NJS 17 pages. Ice machine models with ride technology
installation instructions for drop-ins
Également pour Follett Horizon Elite HCD1410NJS : Manuel (8 pages), Manuel (8 pages)
Connect utilities to louvered docking assembly.
6.1
Water and drain
• Remove access panel if necessary.
• Install drain line
➊
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Rough-in ice machine potable water
➋
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Apply Petrogel to barbed drain fitting
• Replace access panel.
10
➋
➌
➊
.
➌
remote condensing
External connections
6.2
Refrigerant
➊
• Braze supplied expandable refrigerant
lines in place
➊
DROP-IN • RIDE Technology
6