Follett Horizon Elite HMD1410RHT Manuel d'instructions d'installation - Page 13
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Follett Horizon Elite HMD1410RHT. Follett Horizon Elite HMD1410RHT 17 pages. Top-mount applications
Également pour Follett Horizon Elite HMD1410RHT : Manuel d'instructions d'installation (17 pages)
![Follett Horizon Elite HMD1410RHT Manuel d'instructions d'installation](/uploads/products/server2/1276555/1276555.jpg)
Connect utilities to louvered docking assembly.
6.1
Water and drain
• Remove access panel if necessary.
• Install drain line
➊
.
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Rough-in ice machine potable water
➋
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine.
• Apply Petrogel to barbed drain fitting
• Replace access panel.
HARMONY • TOP-MOUNT
➋
➌
➊
➌
remote condensing
External connections
6.2
Refrigerant lines
➊
• Braze supplied expandable refrigerant
lines in place
➊
6