5.

External Connections

5.1

Air-cooled ice machines only

§ Install drain line
(3/4" MPT).
The rigid drain line from the ice machine must have
Front View - Air Cooled
at least 1/4" per foot (6,4 mm/0,3 m) pitch.
§ Install ice machine potable water supply
.
(3/8" FPT)
Note: Follett recommends a Follett water filter
system be installed in the ice machine inlet
water line (standard capacity #00130299, high
capacity #00978957, carbonless high capacity
#01050442).
5.3

Bin Stat Cable

IN from
dispenser
Front View - Water Cooled
RELAY
OUT to
ice machine
§ Route 2-pin bin stat cable from Vision dispenser
Vision • RIDE Technology
CONDENSER
OUTLET
Front View - Air Cooled
5.2

Water-cooled ice machines only

§ Install drain line
Front View - Water Cooled
The rigid drain line from the ice machine must
have at least 1/" per foot (6,4 mm/0,3 m) pitch.
§ Install ice machine potable water supply
(3/8" FPT) .
Note: Follett recommends a Follett water filter
system be installed in the ice machine inlet
water line (standard capacity #00130299,
high capacity #00978957, carbonless high
capacity #01050442).
§ Connect cooling water supply
(3/8" FPT).
ICE MACHINE
Note: Do not apply
power to ice
machine bin signal
connection! Ice
machine can only
see contact closure.
and connect at front of ice machine
Maestro Plus
CONDENSER
OUTLET
(3/4" MPT).
and return
.
11