Follett REF Series Manuel d'installation et d'entretien - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'entretien pour {nom_de_la_catégorie} Follett REF Series. Follett REF Series 16 pages. Undercounter refrigerator
Également pour Follett REF Series : Manuel d'installation et d'entretien (20 pages)

Follett REF Series Manuel d'installation et d'entretien

Welcome to Follett

Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that
you take a moment to review this manual before beginning the installation. Should you have any questions or
require technical help at any point, please call our technical service group at (800) 523-9361 or (610) 252-7301.

Before you begin

After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If
damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the fi ling
of a claim, if necessary.
Check your paperwork to determine which item number you have. Follett item numbers are designed to provide
information about the type of refrigerator you are receiving. Following is an explanation of the different item
numbers.
Model Number
REF5
REF5-00000
REF5-KP0000
REF5-00ST00
REF5-KPST00
REF4-ADA
REF4-000000
REF4-KP0000
REF4-00ST00
REF4-KPST00

Specifi cations

Series specifi cations
REF4-ADA
31.25" height
REF5
34.00" height
Electrical specifi cations
115V, 60Hz, 1 phase
Full load amps: 8.0
Minimum circuit ampacity: 15 amp
Maximum size of branch circuit overcurrent device: 15 amp
Refrigeration specifi cations
Refrigerant – R404A
Charge size – 7.9 oz
Maximum design pressures:
High side – 375psi
Low side – 174psi
Installation specifi cations
Ambient temperature must not exceed 100 F (38 C).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
Important cautions
• Equipment must be wired according to local and NEC codes.
• Always disconnect power before servicing refrigerator.
Item Number
fi ts below 34" high ADA-compatible counter
fi ts below standard 36" high counter
Stackable/Use with
Keypad
Pedestal
X
X
X
X
3
Factory-installed
Chart Recorder
X
X
X
X
4.0 cu ft capacity