Relative Humidity : Maximum relative humidity 80% for temperature up to 31
decreasing linearly to 50% relative humidity at 40
Altitude : Operating below 2000m
Storage Temperature : -20
Temperature Coefficient : nominal 0.15 x (specified accuracy)/
-40
C), or otherwise specified
o
Sensing : Average sensing for model 131; True RMS sensing for model 132 & 135
Safety : Meets IEC61010-2-032(1994), EN61010-2-032(1995), UL3111-2-032(1999).
Measurement Category III 600 Volts ac & dc
Transient protection : 6.5kV (1.2/50µs surge) for all models
Pollution degree : 2
E.M.C. : Meets EN61326(1997, 1998/A1), EN61000-4-2(1995), and EN61000-4-3(1996)
In an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
Overload Protections :
ACA Clamp-on jaws : AC 1000A rms continuous
+ & COM terminals (all functions) : 600VDC/VAC rms
Power Supply : standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2
Power Consumption :
Voltage & ACA functions: 3.5mA typical
Ohm & Temperature functions: 4mA typical
APO Timing : Idle for 16 minutes
APO Consumption : 10µA typical
Dimension : L224mm X W78mm X H40mm
Weight : 224 gm approx
Jaw opening & Conductor diameter : 45mm max
Special features : THD%-R Total harmonic distortion-RMS (ACD-40PQ only); Display
Backlight ACD-16 TRMS & ACD-40PQ only); Auto-Hold; Display Hold; On screen
stand-alone Hi-Lo logging (5400 minutes) at sampling speed of faster than:
20 per second for Voltage & ACA functions
4 per second for Ohm & Temperature functions
2 per second for Hz function
Accessories : Test leads
plug type-K thermocouple & soft carrying pouch
O ptional accessories :
Electrical Specifications
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23
less than 75% R.H.
1.800.561.8187
C to 60
C, < 80% R.H. (with battery removed)
o
o
(MTL-90B)
, batteries installed, user's manual,
RS-232 KIT2
interface kit.
www.
C
o
.com
C
o
C @(0
C -18
C or 28
o
o
o
TPK-59
banana
C ±5
o
12
C
o
C &
o