Follett Symphony REF5 Manuel d'installation et d'entretien - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'entretien pour {nom_de_la_catégorie} Follett Symphony REF5. Follett Symphony REF5 20 pages. Compressor retrofit kit
Également pour Follett Symphony REF5 : Manuel d'instructions d'installation (8 pages)

Follett Symphony REF5 Manuel d'installation et d'entretien

Welcome to Follett

Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that
you take a moment to review this manual before beginning the installation. Should you have any questions or
require technical help at any point, please call our technical service group at (800) 523-9361 or (610) 252-7301.

Before you begin

After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If
damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the filing
of a claim, if necessary.

Specifications

Series specifications
REF4-ADA
31.25" height
REF5
34.00" height
Electrical specifications
115V, 60Hz, 1 phase
Full load amps: 8.0
Minimum circuit ampacity: 15 amp
Maximum size of branch circuit overcurrent device: 15 amp
Refrigeration specifications
Refrigerant – R404A
Charge size – 8 oz
Maximum design pressures:
High side – 375psi
Low side – 174psi
Installation specifications
Ambient temperature must not exceed 100°F (38°C).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
Important cautions
• Equipment must be wired according to local and NEC codes.
• Always disconnect power before servicing refrigerator.
fits below 34" high ADA-compatible counter
fits below standard 36" high counter
3
4.0 cu ft capacity
4.8 cu ft capacity