Removing drawers
1. Pull drawer forward to stop.
2. Lift drawer front to free front rollers from sides.
3. Still lifted, pull drawer forward to free back rollers from sides.
Removing slides
1. Push slides all the way back.
2. Swing bottom of slide away from refrigerator wall and lift slide off of rollers.

Controller replacement

1. Disconnect power to unit.
a. Push front panel rocker switch to OFF position.
b. Disconnect power cord.
2. Remove 6 screws from front panel and slide panel forward to access back of controller.
3. Disconnect front panel and wiring harness from freezer at the 3, 4, and 5 pin connectors and door heater to
simplify replacement.
4. Push in on center of side brackets (on controller) to release and slide brackets back and off controller.
5. Push controller and wires out through front of front panel.
6. Using wiring schematic (attached to front panel and below) as a guide, remove wires one at a time from back
of existing controller and connect to corresponding terminals on replacement controller.
7. Gently remove faceplate from existing controller and install on replacement controller.
8. Insert replacement controller back through front of panel.
9. Slide brackets onto sides of controller and push against back of front panel.
10. Reconnect 3, 4, and 5 pin connectors of wiring harness to freezer.
11. Keeping wiring clear of condenser, replace front panel.
12. Restore power and test operation. Reprogram replacement controller if necessary.

Wiring diagram

COMP
10
11
BLK
12
13
R
S
14
WHT
CONDENSING UNIT
WHT
WHT
L1
120 VAC
WHT
1 PHASE
L2
15 AMPS
GND
GROUND SCREWS
EVAPORATOR
THERMISTOR
CHAMBER
THERMISTOR
DOOR
HEATER
1
2
3
BLU
1
2
3
4
RED
1
2
3
4
5
HEATER
SAFETY SWITCH
DEFROST
DEFROST
FAN
EVAPORATOR UNIT
BLK
1
2
3
1
2
3
4
1
2
3
4
5
10
RED
BLK
BLK
BLU
YEL
WHT
WHT
VIO