Amprobe 15XP-A Manuel de l'utilisateur - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Amprobe 15XP-A. Amprobe 15XP-A 19 pages. Compact digital multimeters
AC CURRENT (45 Hz to 500 Hz)
Ranges: 200 µA, 2 mA, 20 mA, 200 mA,
± (2.0 % rdg + 5 dgts)
RESISTANCE
Ranges: 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ,
2 MΩ, 20 MΩ
Accuracy: ± (1.0 % rdg + 4 dgts) on
200 to 200 kΩ ranges: ± (1.5 % rdg +
4 dgts) on 2 MΩ range: ± (3.0 % rdg +
5 dgts) on 20 MΩ range
CONTINUITY
Audible indication: 75 ± 25 Ω
DIODE TEST
Test current: 1.0 mA (approximate)
Accuracy: ± (1.5 % rdg + 3 dgts)
Open circuit volts: 3.0 dc typical
BATTERY TEST
Ranges: 1.5 V, 9 V
Accuracy: ± (3.5 % rdg + 2 dgts)
OVERLOAD PROTECTION
Voltage, Resistance, Diode, Continuity:
1000 VDC or 750 VAC rms
200 mV Range: 1000 VDC / 750 VAC
rms (3 minutes)
Current: 0.315 A / 1000 V fast blow
ceramic fuse 6.3 × 32 mm
mA JACK: Input warning detects wrong
switch/input jack configuration
AUXILIARY FEATURES
DATA HOLD: Freeze the latest reading
on the display.
MIN/MAX: Record the maximum and
minimum reading in a measurement.
15XP-A Electrical
Specifications
(at 23°C ± 5°C, < 75 % R.H.)
DC VOLTS
Ranges: 200 mV, 2 V, 20 V, 200 V,
1000 V
Accuracy: ±(0.5 % rdg + 1 dgt)
AC VOLTS (45 Hz to 500 Hz)
Ranges: 200 mV, 2 V, 20 V, 200 V,
750 V
Accuracy: ±(1.5 % rdg + 5 dgts) 45 Hz
to 100 Hz on 200 mV range ±(1.5 % rdg
+ 5 dgts) on 2 V to 750 V ranges
DC CURRENT
Ranges: 200 µA, 2000 µA, 20 mA,
200 mA, 2 A
Accuracy: ±(1.0 % rdg + 2 dgts) on
200 µA to 200 mA ranges: ±(2.0 % rdg
+ 3 dgts) on 2 A range
AC CURRENT (45 Hz to 500 Hz)
Ranges: 200 µA, 2000 µA, 20 mA,
200 mA, 2 A
Accuracy: ±(1.5 % rdg + 5 dgts) on
200 µA to 200 mA ranges: ±(2.5 % rdg
+ 5 dgts) on 2 A range
RESISTANCE
Ranges: 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ,
2 MΩ, 20 MΩ, 2000 MΩ
Accuracy: ± (1.0 % rdg + 4 dgts) on
200 to 2 MΩ ranges: ± (3.0 % rdg +
5 dgts) on 20 MΩ range
± {5.0 % (rdg -10 dgt) + 20 dgt} on
2000 MΩ range
CONTINUITY
Audible indication: Less than 25 Ω
DIODE TEST
Test current: 1.2 mA (approximate)
Accuracy: ±(1.5 % rdg + 3 dgts)
Open circuit volts: 3.0 dc typical
LOGIC TEST
Thresholds Logic 1 (Hi): 2.8 V ± 0.8 V
Thresholds Logic o (Lo): 0.8 V ± 0.5 V
Test voltage: TTL 5 VDC
OVERLOAD PROTECTION
Voltage, Resistance, Diode, Continuity,
Logic: 1000 VDC or 750 VAC rms
Current: 2 A / 1000 V fast blow ceramic
fuse 6.3 × 32 mm
mA JACK: Input warning detects wrong
switch / input jack configuration
AUXILIARY FEATURES
DATA HOLD: Freeze the latest reading
on the display.
RANGE: Execute manual range mode.
AUTO Power off: After auto power off,
press (RANGE) button to restart the
meter, and the last reading of
measurement will be returned to the
display.
11