Amprobe ACD-14 TRMS-PLUS Manuel d'instruction - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Amprobe ACD-14 TRMS-PLUS. Amprobe ACD-14 TRMS-PLUS 16 pages. Tech clamp
7
ACA Current clamp-on function
Inputs are made through the clamp on jaws for non-invasive ACA current
measurements.
Press the OFF push button momentarily to power on and off the separate ACA
function (upper) display. The MAX HOLD push button can also be used to power on
this function. This twin ACA function display can be used simultaneously with voltage
measurements or any of the other slide-switch functions (lower display) or it can be
used alone.
CAUTION
Clamp the jaws around only one single conductor of a circuit for load current
measurement. Enclosing more than one conductor of a circuit will result in differential
current (like identifying leakage current) measurement.