Amprobe CT-500 Manuel d'instruction - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Amprobe CT-500. Amprobe CT-500 14 pages. 1000 a flexible neutral current transducer
IntroducIng the ct-500
The CT-500 Flexible Neutral Current Transducer is an optional accessory that
is used to measure current on the Amprobe DM-5 Power Quality Analyzer.
The flexible and lightweight measuring head allows for quick and easy
installation in hard to reach areas.
Cable
Flexible measuring head
Power
indicator
Output
cable
Coupling point of the measuring head
Output terminal plug
Pins of output terminal
Output (Hi)
Not used
COM (Output Lo)
Not used
3.0 to 5.5 V
-3.0 to -5.5 V
Output signal is between pin 3 and 5.
The measuring head is powered via pin 1 and 3 (3.0 to 5.5 Vdc) and pin 2 and
3 (-3.0 to -5.5 Vdc).
Connecting terminal on DM-5 is symmetrical to above pin configurations.
2