Wire Wrap Pin Layouts
and Rear Panel Connectors
J3
Fig. 16 - Wire-Wrap Connectors are Accessed from Rear
2
4
6
8
10
12
14
16
18
20
22
24
26
1
3
5
7
9
11
13
15
17
19
21
23
25
J1 Pin Layout
PIN # DESCRIPTION
1
N/C
3
CTS PORT 1
5
TXD PORT 1
7
N/C
9
CTS PORT 2
11
TXD PORT 2
13
N/C
15
N/C
17
N/C
19
N/C
21
CTS PORT 3
23
TXD PORT 3
25
N/C
27
CTS PORT 4
29
TXD PORT 4
N/C
31
N/C
33
N/C
35
N/C
37
CTS PORT 5
39
TXD PORT 5
41
N/C
43
CTS PORT 6
45
TXD PORT 6
47
N/C
49
N/C
51
N/C
53
N/C
55
Fig. 17 - Non-Connectorized Models Connect Directly to Wire-Wrap Pins at Back of MUX
J9 - J17
PINOUT FOR RS232 INTERFACE
1 ( N/C)
2 ( TXD)
3 ( RCV)
4 ( N/C)
5 ( GND)
J1
J2
28
30
32
34
36
38
40
42
44
46
48
50
52
27
29
31
33
35
37
39
41
43
45
47
49
51
PIN # DESCRIPTION
2
N/C
4
GND PORT 1
6
RXD PORT 1
8
RTS PORT 1
10
GND PORT 2
12
RXD PORT 2
14
RTS PORT 2
16
N/C
18
N/C
20
N/C
22
GND PORT 3
24
RXD PORT 3
26
RTS PORT 3
28
GND PORT 4
30
RXD PORT 4
RTS PORT 4
32
N/C
34
N/C
36
N/C
38
GND PORT 5
40
RXD PORT 5
42
RTS PORT 5
44
GND PORT 6
46
RXD PORT 6
48
RTS PORT 6
50
N/C
52
N/C
54
N/C
56
J9
J10 J11 J12 J13 J14 J15 J16
COMMON PORT
Fig. 18 - Rear Panel of Connectorized Model
PINOUT FOR FUSE ALM & CTRLS
1 (F/A COM)
6 ( N/C)
2 (F/A N.O.)
7 ( DCD)
3 ( N/C)
8 ( DTR)
4 ( N/C)
9 ( N/C)
5 ( N/C)
Fig. 19 - Female DB9 Connector Pin-Outs on Rear of ASCII MUX
Figs. 16 through 17 show the pinouts for J1 and J2 wire wrap
pins a on the rear panel.

Connectorized Model Layouts

Figure 18 shows the back panel of a connectorized MUX.
Refer to Fig. 19 for the connector pin-outs.
J2 Pin Layout
54
56
PIN # DESCRIPTION
1
CTS PORT 7
3
TXD PORT 7
53
55
5
N/C
7
CTS PORT 8
9
TXD PORT 8
11
N/C
13
N/C
15
N.C. CTRL 1*
17
COM. CTRL 1*
19
N/C
21
ALARM 1 -*
23
ALARM 2 -*
25
ALARM 3 -*
27
ALARM 4 -*
29
N/C
31
N/C
33
N/C
35
N/C
37
N/C
39
TXD COMMON (MUX) PORT
41
DCD COMMON (MUX) PORT
43
N/C
45
FUSE ALARM
47
N/C
49
N/C
51
N/C
53
N/C
55
- BATTERY
FUSE ALARM
(NORMALLY OPEN FORM 'A' RELAY)
*For Future Implementation
DB9 FEMALE CONNECTORS
PORTS 1 - 8
FUSE ALARM AND CONTROLS
J18
1 (ALM 1A)
6 (CTRL N.C.)
2 (ALM 1B)
7 (CTRL N.O.)
3 (ALM 2A)
8 (CTRL COM)
4 (ALM 2B)
9 ( N/C)
5 (ALM 3A)
6
PIN # DESCRIPTION
2
GND PORT 7
4
RXD PORT 7
6
RTS PORT 7
8
GND PORT 8
10
RXD PORT 8
12
RTS PORT 8
14
N/C
16
N.O. CTRL 1*
18
N/C
20
N/C
22
ALARM 1 +*
24
ALARM 2 +*
26
ALARM 3 +*
28
ALARM 4 +*
30
N/C
32
N/C
34
N/C
36
N/C
38
DTR COMMON (MUX) PORT
40
RCV COMMON (MUX) PORT
42
GND COMMON (MUX) PORT
44
N/C
46
FUSE ALARM
48
N/C
50
N/C
52
N/C
54
N/C
56
GROUND
45
46
J17 J18 J19
J20 J21 J22
J20 - J22
Not Used
ALARM POINTS 1 - 4
J19
PINOUT ALARM POINTS
6 (ALM 3B)
7 (ALM 4A)
8 (ALM 4B)
9 ( N/C)
D-PC-180-10A-XV
Frame
Ground
GND
-BATT
POWER
TERMINAL
BLOCK
March 1997