Daikin 5MXS48TVJU Manuel d'installation - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Daikin 5MXS48TVJU. Daikin 5MXS48TVJU 20 pages. R410a split series

Daikin 5MXS48TVJU Manuel d'installation

Outdoor Unit Installation

1.

Installing the outdoor unit

• When installing the outdoor unit, refer to "Precautions for Selecting a Location" on page 3 and the "Outdoor Unit
Installation Diagram" on page 4.
• If drain work is necessary, follow the procedures below.
2.

Drain work

CAUTION
• In cold areas, do not use a drain socket, drain plugs and a drain hose with the outdoor
unit. (Drain water may freeze, impairing heating performance.)
• If the drain port is covered by a mounting base or floor surface, place additional foot
bases of at least 3-15/16 inch (100mm) in height under the outdoor unit's feet.
1) Insert the
D
drain plug into the bottom frame until it is flush with the bottom frame
around the entire circumference, as shown in area A.
Be careful not to push in
the drain plug too far.
2) Insert
C
drain socket cap onto
3) Insert
drain socket into the matching drain hole.
B
After insertion, turn it about 40° clockwise.
NOTE
Check that
drain socket cap is correctly engaged with the projection of
C
Otherwise, water leakage may result.
4) Connect the drain hose (field supplied; internal diameter of 1 inch (25mm)) to
socket.
(Ensure there are no bends in the hose if it is too long or hangs down.)
5) Make sure the
D
drain plugs and the
inserted and there is no leakage.
3.

Flaring the pipe end

WARNING
• Do not use mineral oil on flared part.
• Prevent mineral oil from getting into the system as this would reduce the service life of the units.
• Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
• Never install a dryer to this R410A unit in order to guarantee its service life.
• The drying material may dissolve and damage the system.
• Incomplete flaring may cause refrigerant gas leakage.
CAUTION
Do not reuse joints which have been used once already.
1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing
downward so that the chips do not enter the
pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.
English
Area A
Drain plug insert direction
B
drain socket beyond the projection around
B
drain socket of the outdoor unit are securely
Cut exactly at
right angles.
Set exactly at the position shown below.
B
Bottom frame
B
drain socket.
drain socket.
B
B
drain
Flare's inner
surface must be
flaw-free.
Remove burrs.
Flaring
Flare tool for R410A
A
Clutch-type
Clutch-type (Rigid-type)
0-0.020 inch
0.039-0.059 inch
Die
A
(0-0.5mm)
(1.0-1.5mm)
Drain plugs
D
D
Drain plugs
Drain
socket
Air outlet side
B
Drain socket
Projection
C
Drain socket cap
Projection
Check
The pipe end must
be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.
Conventional flare tool
Wing-nut type (Imperial-type)
0.059-0.079 inch
(1.5-2.0mm)
8