User Manual – AS5x61/AS5x62 Programming
12) Choose the desired quadrant mode
to 4 quadrants @ 1 revolution.
There are some limits for this programming: 4 Quadrants: max. 90° for each Quadrant
13) Choose the Breakpoint setting: a) Opt is the optimal Breakpoint, calculated by the DLL.
14) Additional Settings:
15) Click
information, in addition to voltages and angles, is needed to program the AS5x62.
www.ams.com
3 Quadrants: max 120° for each Quadrant
2 Quadrants: max 180° for each Quadrant
1 Quadrant: full 360°
b) BP : set the BP in the BPW field
c) BP_T1: BP setting related to T1 position. Set value into
BPWT1D field
d) BP_T2: BP setting related to T2 position. Set value into
BPWT2D field
HystLevel: Only used with 1Q 0 – 360° to move the BP.
Direction: Set the right direction for the Application, CCW or CW.
This will calculate the real values (scale factor, Breakpoint...). All this
Example:1 Quadrant
Revision 1.0 / 10/31/12
there are a possibility to programm up