DR. ALFRED MULLER AE400 Manuel - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} DR. ALFRED MULLER AE400. DR. ALFRED MULLER AE400 7 pages. Portable anemometer, optional with telescopic mast

METEOROLOGISCHE INSTRUMENTE KG
Technical Data: Wind Speed Sensor W400-1
Sensor type
Measuring Range
Accuracy
Threshold point
Distance per revolution
Impulses per revolution
Distance per impulse
Frequency / speed
Cup diameter
Cup wheel diameter
Connection
Ambient temperature
Ambient humidity
Fastening
body dimensions
Weight
Technical Data: Wind Direction Sensor W400-2
Sensor type
Range
Accuracy
Damping ratio
Overswing
Potentiometer linearity
Potentiometer resistance
Potentiometer supply
Vane turning radius
Connection
Ambient temperature
Ambient humidity
Fastening
body dimensions
Weight
DR. ALFRED MÜLLER
R. FUESS
: Cup wheel anemometer with dry-reed contact
and 4 Alpha magnets
: 0...50 m/s rsp. 0...100 kn
: 3% of measuring value
: 0.3 m/s
: 1 m
: 4
: 0.25 m
: 4 Hz / m/s
: 45 mm
: 160 mm
: 6 m cable with 5 pin circular plug
dry – reed – contact between pin 4 and pin 5
: -40°C...+60°C
: 0...100 % RH
: female thread M8
: 35 mm (D) x 142 mm (H)
: 0.5 kg
: Wind vane with ring potentiometer
: 1°...359°
: +/- 2°
: 0.3 m/s
: < 10°
: 0.3 %
: 5 k Ohm
: 50 V / 10 mA max.
: 130 mm
: 6 m cable with 5 pin circular plug
pin 1 : poti 3 / pin 2 : poti 2 / pin 3 : poti 1
: -40°C...+60°C
: 0...100 % RH
: female thread M8
: 35 mm (D) x 142 mm (H)
: 0.5 kg
5