Bosch Ascenta SHE5AM02UC Instruction de réparation - Page 21

Parcourez en ligne ou téléchargez le pdf Instruction de réparation pour {nom_de_la_catégorie} Bosch Ascenta SHE5AM02UC. Bosch Ascenta SHE5AM02UC 27 pages. Quick reference instructions
Également pour Bosch Ascenta SHE5AM02UC : Manuel d'instructions d'installation (21 pages), Manuel de l'énergie (2 pages), Commencer (2 pages), Instructions de réparation (50 pages)

Bosch Ascenta SHE5AM02UC Instruction de réparation
Power
module
6.1.4.3 Door latch
SHE5AM digital display
E:06 Sensor error
Door latch sensor not detected,
functional safety error.
Align door latch above sensor
(located inside inner door).
Sensor located
under tray
Sensor (at top
of inner door)
702_58300000130262_ara_en_b
SHE4AM / SHX3AM
LED display
Door latch (on tank)
6.1.4.4 Heating (heat pump)
SHE5AM digital display
E:08 No load in heat pump
No water in heat pump
Check water supply
E:09 Burn through / safety relay error
Power module controlling relay not
switching / stuck closed
Replace power module
E:10 Resistance too high
Heater resistance too high
Replace heat pump
E:11 NTC1 / NTC 2 failure (absolute /
symmetry)
NTC1 to NTC 2 internal check
failed, functional safety error.
Replace heat pump
E:12 Heater NTC's comparison check
failed
Heater
NTC's
resistances
Replace heat pump
E:13 Water temperature too high
Boil protect level (75ºC / 167ºF)
exceeded, functional safety error.
Replace heat pump
SHE4AM / SHX3AM
LED display
Same LED display
shows
for
codes E:08 – E:13.
have
different
Page 21 of 27
error