TECHNICAL PROBLEMS
THE UNIT WON'T START UP...
SOLUTION :
1) Check if the LED is lit.
2) Check the circuit breaker in your electrical panel.
3) Check the unit's circuit fuse/breaker.
4) Check the 24-volt circuit, as follows :
Establish an electrical contact between the two 24V circuit terminals of the unit with a
metal object such as a screwdriver or a coin.
• If the unit starts up, either the 24V wire is cut or disconnected from one of the
wall inlets, or the hose is defective.
• If the unit does not start up after all theses steps, the printed circuit is defective.
THE UNIT WON'T SHUT DOWN...
SOLUTION :
Check the 24-volt circuit as follows :
Disconnect one of the two wires on the unit's 24-volt circuit.
• If the unit shuts down, the problem could be that two 24-volt wires are touching
themselves somewhere or that the wall inlet is defective.
• If the unit doesn't shut down, the printed circuit is defective.
Unplug the power cord.