Également pour Bosch 300 Series : Manuel d'utilisation (40 pages), Manuel de l'utilisateur (21 pages), Manuel d'installation (6 pages), Manuel d'installation (36 pages), Manuel d'installation (32 pages), Manuel d'utilisation et d'entretien / Instructions d'installation (40 pages), Manuel d'utilisation (50 pages), Manuel de démarrage rapide et de sécurité (7 pages), Manuel d'installation (28 pages), Manuel de démarrage rapide (7 pages), Manuel de démarrage rapide et de sécurité (7 pages), Manuel d'entretien (36 pages), Manuel de démarrage rapide et de sécurité (13 pages)

Bosch 300 Series Manuel d'utilisation et d'entretien
Resetting the saturation displays
Metal grease filter: Press and hold the "+" button for 5
seconds.
Activated carbon filter: Press and hold the "-" button
for 5 seconds.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display
must be switched over accordingly:
The extractor hood must be connected and switched
off.
Press the "+" and "-" keys simultaneously until "Able"
lights up briefly on the display panel.
Repeatedly press the button combination to switch the
electronic control display back to exhaust air mode.
"None" appears on the display panel.
Timer
The timer has no influence on the functions of the exhaust
hood. The duration of the timer can be set to between 1
minute and 60 minutes. The default setting is 10 minutes.
1. Press the "Timer" button.
10 flashes on the display panel.
2. Set the required duration with the "+" and "-" buttons.
After 5 seconds, the time that has been set is adopted.
An audible signal sounds once the time has elapsed
and "End" appears on the display panel for 3 seconds.
Note: To switch off the timer earlier, press any button.
Fan back flow
The run-on time is ten minutes and cannot be changed.
1. Select ventilator setting.
2. Press "Timer" button for 3 seconds.
Once this time has elapsed, the ventilation and lighting
switch off automatically. The display shows the message
"End."
The ventilator run-on can be interrupted at any time by
pressing one of the buttons.
Page 6
Audible signal
Switching on audible signal
Press and hold the "Light" button for 5 seconds.
An audible signal sounds and "Snd" appears on the
display panel for 3 seconds.
Switching off audible signal
Press and hold the "Light" button for 5 seconds.
"Snd" appears on the display panel for 3 seconds.
Overheating protection
The appliance is equipped with overheating protection. If
high temperatures are measured on the appliance, the
appliance switches automatically to the highest ventilator
setting until the temperature drops again.
If the hood is switched on, the highest ventilator setting
is set. If the temperature drops again, the appliance
switches back to the previously-selected ventilator
setting.
If the hood is switched off, the appliance switches
automatically to the highest ventilator setting. If the
temperature drops again, the appliance switches off
automatically.
While the overheating protection is active, "Auto"
appears on the display panel. The ventilator setting
cannot be reduced in this time.