Également pour Draper Envoy : Instructions d'installation et d'utilisation (3 pages), Instructions d'installation et d'utilisation (3 pages), Instructions d'installation et d'utilisation (2 pages), Instructions d'installation et d'utilisation (2 pages), Instructions d'installation et d'utilisation (2 pages), Instructions d'installation et d'utilisation (3 pages)

Draper Envoy Instructions d'installation et d'utilisation
220V Envoy by Draper
Back of wall switch.
Please Note: Although both
Dry Contact and Data Cable
connections are shown, you
should only use one connec-
tion type per motor.
ILT Switch-to-Motor—Dry Contacts or Data Cable connection
U
D
C
P
O
O
W
M
N
M
O
N
External Low Voltage & Wireless Control
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Two-Way Serial Communication (RS232) with MC1
White or Blue-Common
Red-to Screen (directional)
Black-to Screen (directional)
Brown-Hot to AC
Program LED
Green/Yellow-Ground
Fuse
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED
MC1
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
www.draperinc.com
Motor Data Cable
plugged in here
5V
UP 5V COM DWN
White or Blue-Common to screen & 110/220V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110/220V AC-Hot
Black-to 110/220V AC-Hot
Green/Yellow (Ground)
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
Low Voltage Wiring by others
AC Wiring by electrician
To AC Line
(765) 987-7999
Please Note: This Splitter/
Jack is located inside the junc-
tion box of your screen.
Data Cables to switches or
to additional motors can
be plugged into any of the
three open jacks. If this is a
"Case First, Screen Later"
installation, plug the motor
cable into the jack indicated
in the drawing.
Internal Screen Wiring
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Green/Yellow
(Motor Ground)
To
110/220V
Line
STOP
Location of key
operated on-off
switch if furnished
STOP
Control
Switches
24v DC
Internal Screen Wiring
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Green 110V/
Green/Yellow 220V
(Motor Ground)
See separate Serial Communica-
tion-RS232 Instruction sheet for
Location of key
enabling RS232 with the MC1.
operated on-off
switch if furnished
Page 3 of 3