AirStage ASYA14GACH/ASHA14GACH Manuel d'installation - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} AirStage ASYA14GACH/ASHA14GACH. AirStage ASYA14GACH/ASHA14GACH 15 pages. Indoor unit

AirStage ASYA14GACH/ASHA14GACH Manuel d'installation

2.3. Accessories

For installation purposes, be sure to use the parts supplied by the manufacturer or
other prescribed parts.
The use of non-prescribed parts can cause serious accidents such as the unit to fall,
water leakage, electric shock, or fi re.
The following installation parts are furnished. Use them as required.
Keep the Installation Manual in a safe place and do not discard any other accessories
until the installation work has been completed.
Do not discard any accessories needed for installation until the installation work has been
completed.
Name and Shape
Operating Manual
Installation Manual
Wall hook bracket
Cable tie
Cloth tape
Tapping screw (M4×25mm)
Connecting cable
Air cleaning filter
Air cleaning filter frame
Seal A

2.4. Optional parts

Description
Part No.
External output wire B
9379529013
External input wire D
9368779016
External input wire F
9368779023
External input wire B
9368778002
External input wire E
9368778019
WARNING
Q'ty
Application
1
(This book)
1
For indoor unit installation
1
For remote controller cable binding
1
For indoor unit installation
1
For wall hook bracket installation
8
For wired remote controller installation
1
For installation, refer to the
"CLEANING AND CARE" in the
operating manual.
2
2
For indoor unit installation
1
Application
For output port
For control input port
(Apply voltage terminal)
For control input port
(Dry contact terminal)
For forced thermostat off port
(Apply voltage terminal)
For forced thermostat off port
(Dry contact terminal)

3. INSTALLATION WORK

Correct initial installation location is important because it is diffi cult to move unit after it is
installed.

3.1. Selecting an installation location

Select installation locations that can properly support the weight of the indoor. Install
the units securely so that they do not topple or fall.
Do not install the unit in the following areas:
• Area with high salt content, such as at the seaside.
It will deteriorate metal parts, causing the parts to fail or the unit to leak water.
• Area fi lled with mineral oil or containing a large amount of splashed oil or steam,
such as a kitchen.
It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.
• Area that generates substances that adversely affect the equipment, such as sulfuric
gas, chlorine gas, acid, or alkali.
It will cause the copper pipes and brazed joints to corrode, which can cause
refrigerant leakage.
• Area that can cause combustible gas to leak, contains suspended carbon fi bers or
fl ammable dust, or volatile infl ammables such as paint thinner or gasoline.
If gas leaks and settles around the unit, it can cause a fi re.
• Area where animals may urinate on the unit or ammonia may be generated.
Do not use the unit for special purposes, such as storing food, raising animals, growing
plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.
Do not install where there is the danger of combustible gas leakage.
Do not install the unit near a source of heat, steam, or fl ammable gas.
Install the unit where drainage does not cause any trouble.
Install the indoor unit, power supply cable, transmission cable, and remote controller
cable at least 1 m away from a television or radio receivers. The purpose of this is to
prevent TV reception interference or radio noise.
(Even if they are installed more than 1 m apart, you could still receive noise under
some signal conditions.)
If children under 10 years old may approach the unit, take preventive measures so that
they cannot reach the unit.
Decide the mounting position with the customer as follows:
(1) Install the indoor unit on a place having a suffi cient strength so that it withstands
against the weight of the indoor unit.
(2) The inlet and outlet ports should not be obstructed; the air should be able to blow all
over the room.
(3) Leave the space required to service the air conditioner.
(4) A place from where the air can be distributed evenly throughout the room by the unit.
(5) Install the unit where connection to the outdoor unit (or RB unit) is easy.
(6) Install the unit where the connection pipe can be easily installed.
(7) Install the unit where the drain pipe can be easily installed.
(8) Install the unit where noise and vibrations are not amplifi ed.
(9) Take servicing, etc., into consideration and leave the spaces. Also install the unit
where the fi lter can be removed.

3.2. Installation dimensions

Provide a service space for inspection purposes.
Do not place any wiring or illumination in the service space, as they will impede service.
50 mm or
over
60 mm or over
1,500 mm or over
1,800 mm or over
WARNING
CAUTION
Wall hook bracket
90 mm or
over
(Wall cap)
Drain hose
O.D 15.8 to 16.7 mm
I.D 13.8 mm
En-2