11. MAINTENANCE

11.1 BEFORE-USE MAINTENANCE CHECKS

Before connection to the air supply:
− Drain the compressor reservoir of condensate.
− Drain the air lines of condensate.
− Drain the combined separator filter, regulator, water trap.
− Fill up the combined separator filter, regulator, lubricant reservoir.
− Check the line pressure is correct for the tool.

11.2 AFTER-USE MAINTENANCE CHECKS

− Repeat the above procedures.
− Lubricate the tool with approximately 1.5ml of oil directly down the air inlet.