Efficiencv:
Variable switchmode dc input combined with Class D
Fetpower™ output provides a minimum 60% overall efficiency from 100
watts to 600 watts output into 50 ohms resistive.
Regulation:
Forward power or dc bias of the load.
Input Power:
115 VAC + 10% or 230 VAC
±
10% single phase, 50/60
Hz.
Dual Supply operation:
unit may operate either as master or slave
or
independent
mode
by
logic
level
selection
through
a
user
connector on the rear panel (common exciter - "CEX TOGGLE") .
Remote Operation:
A user connector (25-pin subminiature D-type) is
provided on the rear panel to allow remote operation or computer
interface.
Diaqnostic Connector:
Rear panel subminiature (IS-pin subminiature
D-type) connector provides sufficient information to troubleshoot
a problem to an internal module level without the need to open the
cover.
Cooling:
Forced air; maximum inlet ambient temperature is 40°C.
Temperature monitors protect the unit from fan failure or airflow
blockage.
Size:
6.97 in.
(17.70 cm) Height
8.50 in.
(21.59 cm) Width*
17.75 in (45.09 cm) Deep
*Add 2 inches (5.08 cm) to include removable rack ears
Weight:
26.5 lbs. (12 Kg)
RF Output Connector:
Type
"N"
8