AirStage AUXD18GALH Manuel d'utilisation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} AirStage AUXD18GALH. AirStage AUXD18GALH 6 pages. Indoor unit (cassette type)
Également pour AirStage AUXD18GALH : Manuel d'installation (17 pages)
● The OPERATION indicator lamp (green) and TIMER indicator lamp
(orange) are fl ashing simultaneously:
It is operating in trial operation mode. Ask a manager as there may be
maintenance being conducted.
● The OPERATION indicator lamp (green) lights up and the TIMER
indicator lamp (orange) fl ashes:
This is the standby state. (See page 2)
Noise is heard:
● In the following conditions there are sounds of water fl owing from the
indoor unit and the operation sound becomes loud. These are the
sounds of the fl owing of refrigerant.
When operation starts
When oil recovery operation fi nishes
When automatic defrosting operation fi nishes
● During operation, a slight squeaking sound may be heard. This is the
result of minute expansion and contraction of the panel due to tem-
perature changes.
● During Heating operation, a sizzling sound may be heard occasionally.
This sound is produced by the Automatic Defrosting operation. (See
page 2)
Smells:
● Some smell may be emitted from the indoor unit. This smell is the
result of room smells (furniture, tobacco, etc.) which have been taken
into the air conditioner.
Fog comes out of the indoor unit:
● During Cooling operation, a thin mist may be seen emitted from the
indoor unit. This results from the sudden Cooling of room air by the air
emitted from the air conditioner, resulting in condensation and misting.
Steam comes out of the indoor unit:
● During Heating operation, the outdoor unit's fan may stop, and steam
may be seen rising from the unit. This is due to the Automatic Defrost-
ing operation. (See page 2)
Water is produced from the outdoor unit:
● During Heating operation, water may be produced from the outdoor
unit due to the Automatic Defrosting operation.
The following conditions may not be breakdowns so
check again.
Doesn't operate at all:
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the main power switch set to the OFF position?
● Are you trying to engage in an operation different from the priority
state? (See page 2)
● Is it in standby state? (See page 2)
The operation mode cannot be changed:
● Are you trying to change to an operation different from the priority
conditions? (See page 2)
Poor Cooling (or Heating) performance:
● Did you adjust the room temperature settings (thermostat) correctly?
● Is the air fi lter dirty? (See page 2)
● Are the air conditioner's inlet port or outlet port blocked?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
● Is the fan speed set to low?
Set the temperature lower than the room temperature and use it:
● Temperature does not fall down well. Temperature may not fall down
depending on the room conditions. (While high humidity or the room
temperature is high.) (See page 2)
In the following situations stop operation immediately
and get in touch with authorized service personnel.
● The problem cannot be solved even when the troubleshooting checks
have been performed.
● The FILTER indicator lamp (red) is fl ashing very fast.
● The wired remote controller or simple remote controller indicate Er
(when connected).
● It has burning smell.
AMP Air Conditioning
SPECIFICATIONS
AUXB
AUXB
MODEL
04
07
GALH
GALH
POWER SOURCE
AVAILABLE VOLT-
AGE RANGE
COOLING
[kW]
1.1
2.2
CAPACITY
HEATING
[kW]
1.3
2.8
CAPACITY
SOUND PRESSURE LEVEL (COOLING/HEATING)
HIGH
dB [A] 34/34
34/34
MED
dB [A] 30/28
30/30
LOW
dB [A] 25/21
25/25
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
AUXD
AUXD
MODEL
18
24
GALH
GALH
POWER SOURCE
AVAILABLE VOLT-
AGE RANGE
COOLING
[kW]
5.6
7.1
CAPACITY
HEATING
[kW]
6.3
8.0
CAPACITY
SOUND PRESSURE LEVEL (COOLING/HEATING)
HIGH
dB [A] 36/36
38/38
MED
dB [A] 30/30
33/33
LOW
dB [A] 29/29
29/29
DIMENSIONS & WEIGHT
HEIGHT
[mm]
246
WIDTH
[mm]
840
DEPTH
[mm]
840
WEIGHT
[kg]
22
Acoustic Noise Information :
The maximum sound pressure level is less than 70 dB (A) for both indoor
unit and outdoor unit. According to IEC 704-1 and ISO 3744.
www.ampair.co.uk | [email protected]
AUXB
AUXB
AUXB
AUXB
AUXB
09
12
14
18
24
GALH
GALH
GALH
GALH
GALH
230 V ~ 50 Hz
198 to 264 V
2.8
3.6
4.5
5.6
7.1
3.2
4.1
5.0
6.3
8.0
35/35
37/37
38/38
41/41
50/50
30/30
34/34
34/34
35/35
44/44
25/25
27/27
27/27
27/27
30/30
245
570
570
15
17
AUXA
AUXA
AUXA
AUXA
AUXA
30
34
36
45
54
GALH
GALH
GALH
GALH
GALH
230 V ~ 50 Hz
198 to 264 V
9.0
10.0
11.2
12.5
14.0
10.0
11.2
12.5
14.0
16.0
40/40
43/43
44/44
46/46
47/47
38/38
38/38
38/38
39/39
39/39
33/31
33/31
33/31
33/31
33/31
288
840
840
27
En-4