MODEL CDG420 INSTALLATION INSTRUCTIONS
CDG420
Template Size 2-4 Door Closer c/w Bracket
1121-CPD-AD5462
SELECTING THE CORRECT DOOR CLOSER TO SUIT DOOR SIZE
Minimum size 3 MUST be used on fire doors.
Hold open arms must NOT be used on fire
doors.
* Minimum size for use on fire doors.
The door closer power adjustment is controlled by the position of the mechanism on the door/transom, and the direction of
Fig 1 - Standard Application
(pull side)
The mechanism is in the same position for
power sizes 2 & 3, but power size 4 is further
from the hinge side of the door.
Note: Please refer to 1:1 scale template for
Fig 1 application, taking care to select the
correct positions on the template to suit
width and mass of the door.
The adjustment valves for the
latching/closing must face towards the
hinge side.
Fig 1 Power Shoe Detail
Power Size
3-4
Hinge
Side
Power Size
2
PLEASE LEAVE THESE INSTRUCTIONS WITH THE END USER
Declarations of Performance, and other information can be downloaded from www.carlislebrass.com
Tel: 01228 511030 Fax: 01228 511885 Web: www.carlislebrass.com
FITCB0040 - Rev A 19/12/19
Template Size 2-4 Door Closer c/w Fig. 6 Bracket
EN 1154: 1996 + A1: 2002 +AC: 2006
Fig 1
3
Fig 6
3
Fig 61
3
I M P O R T A N T I N F O R M A T I O N
Power Size
the power show. Details for each application are below:
F
ig 6 - Parallel Mount Application
Suitable in power size 3 only.
Note: Please refer to the 1:1 scale
template for Fig 6 application.
The adjustment valves for
latching/closing must face away from
the hinge side.
Fig 6 Power Shoe Detail
Hinge
Side
Carlisle Brass Ltd.
Parkhouse Road, Carlisle, CA3 0JU
20
4
8
1
2
8
3
1
3
8
1
2
Max. Width of Door
2
850mm
3*
950mm
4
1100mm
(push side)
Power Size
3
1
3
1
3
1
3
Max. Mass of Door
40Kg
60Kg
80Kg
Fig 61 - Transom Mount Application
(push side)
Head Projection is limited to 30mm.
Suitable for power sizes 2 & 3 only.
The mechanism position on the
transom/frame us the same for both.
Note: Please refer to 1:1 scale template
for Fig 1 application for the required
dimensions to use in transom mount
application, taking care to select the
correct position on the template.
The adjustment valves for
latching/closing must face away from
the hinge side
Fig 61 Power Shoe Detail
Power Size
3
Hinge
Side
Power Size
2