We recommend checking and cleaning the tank from lime scale and eventual replacement
of the anode rod after two years of operation. The anode life is theoretically calculated for two
years of operation; however, it changes with water hardness and chemical composition
in the place of use. Based on such an inspection, the next term of anode rod exchange may be
determined. If the anode is only blocked with sediments clean its surface and, if used up, mount
a new one. Have a company in charge of service affairs deal with the cleaning and exchanging
of the anode.

2.9 MOST FREQUENT FUNCTION FAILURES AND THEIR CAUSES

FAILURE SYMPTOM
Water is cold
Water is cold
Water is not warm enough
Temperature of water is not
corresponding with the
temperature set on the
control
Water is constantly dripping
off the safety valve
Do not attempt to repair the failure yourselves. Seek either expert or service help. It does not
take much for an expert to remove the defect. When making a repair appointment, report
the type and serial number you find on the performance plate of your water heater.
INDICATOR
Light on
Light off
Light on
Light off
Table 4
SOLUTION
The temperature set on the thermostat
is too low
Heating element failure
No supply voltage!
Thermostat failure
Safety thermostat shut off probably due
to failed operation thermostat
heating element failure
Defective thermostat
high input pressure
defective safety valve