CARLO GAVAZZI CD34CNFLFNCT5 Manuel rapide

Parcourez en ligne ou téléchargez le pdf Manuel rapide pour {nom_de_la_catégorie} CARLO GAVAZZI CD34CNFLFNCT5. CARLO GAVAZZI CD34CNFLFNCT5 9 pages. Capacitive sensor, foreground suppression

CARLO GAVAZZI CD34CNFLFNCT5 Manuel rapide
CD34CNFLFxxx
Capacitive sensor, Foreground Suppression
Description
The CD34.. capacitive sensor is designed for
detecting water-based (conductive) liquids through
a non-metallic container wall, and it automatically
adapts to various thicknesses of plastic or glass
walls.
The universal mounting brackets allow the sensor
to be fixed on various tubes or containers.
Strong, compact housing with IP69K ratings and
ECOLAB approval for wash-down applications.
The sensor will function out of the box in most
applications, and teach-in capabilities are available
for adapting the sensor to more challenging
applications.
21/02/2018
CD34CNFLFxxx ENG
Main features
Compact housing
Supply voltage: 10 to 30 VDC
Output: 100 mA, NPN or PNP preset
Make or break switching function
LED indication for output and power ON
Protection: reverse polarity, short circuit and transients
Cable and pigtail M8 plug versions
Excellent EMC performance
IP65, IP66, IP67, IP68 and IP69K for hose-down
applications
cULus
Ecolab
Main functions
Detection of water-based fluids inside a container or tube
without direct contact with the fluids.
The sensor detects the liquids reliably while compensating
for residue film, moisture or foam build-up from liquids
such as water, milk, body fluids (blood), acid- or alkaline
solutions with conductivity as high as 50 mS/cm inside or
outside the container wall.
Flexible and fast universal mounting bracket.
The sensing principle detects only the level of the liquids
while ignoring foam, film or build-up that would cause
standard capacitive sensors to detect faultily.
1
Carlo Gavazzi Industri A/S