Alen AMS12 12000 BTU AND 13.5 SEER Manuel d'installation - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Alen AMS12 12000 BTU AND 13.5 SEER. Alen AMS12 12000 BTU AND 13.5 SEER 17 pages. Split type room air conditioner 9000 btu and 14.5 seer/12000 btu and 13.5 seer

EvAPORATOR INSTALLATION (INDOOR)
The Installation Plate would look like one of the
following (Depending on the models):
Installation plate and its dimensions (Unit: Inches)
Evaporator (Indoor) Unit Outline
4.7 inches or more
to the wall
Left refrigerant
pipe hole O 2.56"
Evaporator (Indoor) Unit Outline
4.72 inches or more
to the wall
Left refrigerant
pipe
hole O 2.56"
1) Mounting Installation Plate
i) Fix the installation plate
1) Install the installation plate horizontally on structural parts in the walls with the spaces
provided around the plate.
2) In case of brick, concrete or similar type of walls, Make holes in the wall. Insert clip anchors
for appropriate mounting screws.
3) Fix the installation plate on the wall.
6" inches or more to ceiling
32.09"
(<12000Btu/h model)
6 inches or more to ceiling
1.65"
35.67"
2.17"

Installation Plate

8
Installation Plate
4.7 inches or more
to the wall
1.97"
Right refrigerant
pipe hole O 2.56"
Installation Plate
1.93"
4.72 inches or more
to the wall
Right refrigerant
3.54"
pipe hole O 2.56