C - Smoke Outlet Port
While set up the unit, the Smoke Delivery Hose need to be mounted onto the Smoke Outlet .
D - Power Socket
While set up the unit, the power cords need to plug into the power socket.
E,F - State Indica�on and Air Control
The <E - LED Indication> LED has two states.
RED: Power ON.
GREEN: Pressurized air produc�on.
While power up the unit, the LED would turn RED.
Press <F - Air Control switch>, the <E - LED Indication> would turn GREEN, and the unit start
to generate pressurized air.
Press <F - Air Control switch> again any�me, the <E - LED Indication> would turn RED, and
the unit stops genera�ng pressurized air.
G,H - State Indica�on and Smoke Control
The <G - LED Indication> LED has three states.
OFF: Smoke genera�on not started.
GREEN: Smoke genera�on.
RED: Overheat.
While not smoke the unit, the LED would be OFF.
Press <H - Smoke Control switch>, the <G - LED Indication> would turn GREEN, and the unit
start to generate smoke.
Press <H - Smoke Control switch> again any�me, the <G - LED Indication> would turn OFF,
and the unit stops genera�ng smoke.
While the smoke genera�ng chamber is overheat, for protec�on, the smoke genera�on
would be halted and the <G - LED Indication> would turn RED and restart genera�ng smoke while
the smoke genera�ng chamber cooled down, or you can switch it OFF by pressing <H - Smoke
Control switch> .
I - System Pressure Gauge
The Pressure Gauge displays the output pressure of the machine if block the smoke outlet port,
otherwise it shows the real �me pressure of the system been tes�ng.
Pressure Decay Test: This gauge can also be used to determine if a leak exists by switching off the
<F - Air Control> while the system is under pressure. If the gauge holds the displayed pressure,
there is no leakage. If the displayed pressure starts drops, there is leakage in the system.
J - Flow Meter
The purpose of the flow meter is to provide a quick visual indica�on of the amount of air/smoke
passing through the system being tested. If the smoke nozzle is in a closed system, and there are
no leaks in that system, the flow meter will read zero (ball at bo�om of scale). As the system is
filled with air or smoke, the ball in the flow meter will slowly fall to the bo�om of the scale as the
pressure in the system equalizes to the output pressure of the unit. As the flow decreases, the
output pressure will increase. If the flow meter ball never falls to the bo�om of the scale, there is
leakage or air passing through the system. It is not necessary to use smoke when using the flow
meter to determine if a leak exists.
K - Flow Dial
In many cases excessive smoke exi�ng a leak may make it difficult to determine the exact loca�on
of the leak. The purpose of the Flow Control Valve is to decrease the amount of smoke exi�ng a
leak so that its posi�on may be pinpointed without the masking effect of excessive smoke. Turn
clockwise to decrease flow, counterclockwise to increase flow. This valve is also used to lock out
the system under test and observe any pressure decay on the pressure gauge.