1)
Before being packed, the liquid inside the fuel tank should be drained completely to avoid overflowing as
transporting.
2)
Move only by hand or lift with soft belt.
3)
No package no lifting tools or long-distance transportation.
4)
To prevent the unit from shocking and knocking, make sure it is on the base seat and in the packing case during
transportation. Firstly pack the unit with the matter similar with plastic strip and add the filling material (such as
foam or sponge, etc.) between the unit and packing case to avoid scratching the surface when the unit shakes.
5)
Make sure that the maximum incline angel does not exceed 45℃. Do not place the unit up-side-down.
Storing
6.2
1)
Store only in dry area and keep away from water before the unit is unpacked.
2)
Store the machine in well-ventilated area and do not expose it to direct sun shine or rain.
Installation Environment
6.3
1)
Keep a distance of no less than 200mm between the unit and any wall or other substance. The unit should be put
in well-ventilated area. Make sure the temperature is within -10℃+40℃.
2)
The unit has been well grounded for safety operation. Please confirm that the power socket is also well
grounded.
VII. Troubleshooting & Precautions
Troubleshooting
7.1
1)
The unit does not correspond when it is switched on.
2)
Check the fuse at lower right side of the unit and replace it if it is damaged or broken.
3)
There is leakage in the fuel separator coupler.
4)
Fuel leaked at coupling element of fuel separator. Please check whether the "O" ring installed matches and if it deformed or
damaged. If it does not match or is damaged, please change it. The two black adjusting screws should not be too tight, which
may also cause the coupling element of fuel separator to leak fuel.
5)
The used machine has not been used for a long time about several months, and it is found that the pump cannot work normally.
6)
The type of test liquid used is not suitable, which will lead to poor internal signal of the pump after a long time of non-use. Use
the electrical shock method and tap the pump as needed to resume normal operation.
Precautions
7.2
1)
In order to avoid electric shock, keep away from the damp part of a working unit and avoid exposing it to the rain.
2)
To ensure operation safety, please make sure that equipment has been connected to ground well.
3)
Do not operate equipment with a damaged cord or if the equipment has been dropped or damaged until it has been examined
by qualified service personnel.
4)
Equipment use is strictly prohibited fireworks, and posted "No smoking" and "Flammable hazard warning" signs.
5)
Please operate the unit according to the operation procedures in the manual. Only use the accessories recommended by the
manufacturer.
6)
ALWAYS WEAR SAFETY GOGGLES. Common used glasses are NOT safety glasses.