1. Quick Setup and Verification

1.1 The following steps demonstrate the basic setup of the ME1110 training kit together with an
oscilloscope.
Step 1: Setting Up the Device Connections
Step 2: Selecting the Modulation Format and Verifying the Waveforms on the Oscilloscope
Step 3: Displaying the Modulated IQ Signals in the 89601 VSA software
The training kit can be damaged by excessive power levels from the instruments. Please adhere
strictly to the power levels recommended in the instructions.
Turn off the training kit when it is not in use.
Step 1: Setting Up the Device Connections
Note: If only an oscilloscope with
analog channels is used (without
the digital channels), skip step 1.
Connect the Clock (J6A),
1
Baseband Data (J6B), and
Symbol Clock (J6C) output to
the oscilloscope's digital
channel 0-2 through the Digital
Probe (Flying Leads).
 Connect the I signal output
2
(TP1) to the oscilloscope's
channel 1 through the
oscilloscope's probe.
Connect the Q signal output
3
(TP2) to the oscilloscope's
channel 2 through
oscilloscope's probe.
4
Connect the RF out signal to
the oscilloscope's channel 3
by using a BNC-to-SMA
coaxial cable.
 Supply a 5 V input voltage to
5
the receiver module and
power it up.
 Make sure all devices are
6
properly connected before
proceeding to the next step.
ME1110 Digital Modulation Technique
IMPORTANT
2
1
5
http://dreamcatcher.asia/cw
3
Quick Start Guide - 6/16