ASSEMBLY OF 30' NAVI-TRAC CLEARSPAN (CS) UNITS
NAVI-TRAC LT Clearspan (CS) units are installed with the same procedure as the Gabled-Gabled End style previously
described, except the bay spacing is a maximum of 10 ft. The 30 ft clearspan is not available in the hip-end configu-
ration. Also, the baseplates are hinged, allowing the beams to be pivoted to vertical. For this reason, the Clearspan
footprint can be laid out ahead of time, with baseplates positioned and anchored to the ground. The 30' Clearspan units
differ from the LT (Lite) unit in the following important ways:
1. The 30' Clearspan units have no external guy webs.
2. The 30' Clearspan units are laid out with 10' maximum bay spacing.
3. All 30' Clearspan bays are X-cabled in the lower roof area above the eave.
4. The wing area of the Gabled End frame is cabled with single opposing cables on each side of the end, as shown
above.
5. The baseplates of all uprights (legs) are hinged (see parts # BH & BHG on page 4), so that the beam can be pivoted
to vertical after the baseplate has been secured to the ground or to appropriate footings. The baseplates have (4)
holes for staking or other anchoring.
6. Uprights are non-adjustable and have a maximum eave height of 8'-0".
The Gabled End technique of standing the second beam of the unit first and stabilizing it with safety guys
should still be used in installing the Clearspan units in order to provide a safe procedure in the initial stages of
assembly before the first bay is stabilized.
NOTE: (2) 1" x 30" steel stakes are provided for each baseplate. The actual loading may require additional
stakes or other anchoring methods to properly meet the loads defined on the blue print or the summary of
engineering analysis. It is the customer's responsibility to insure that proper anchoring is used to meet the
required loads.
To Attach Ground Bars At Gable End Corner of CS NT-LT
Ground Bar (Gable
End)
CS (4) Hole Gable End Corner base plate
Ground Bar (Side)
Gable end ground bar pin fi ts
onto end of L-pin for attachment
of Gable end ground bar.
19